1. BANDWIDTH: External bandwidth (Internet Transit) must be in the form of dedicated circuits with at least 400Mb of throughput delivered over redundant 1Gb Ethernet links. Preference may be given to proposals that contain higher capacity and more detailed redundancy planning. The same carrier may provide redundant lines, though multiple carriers are preferred. Required specifications for the circuit:
2. ROUTING: With single carrier situations, static routing is acceptable as long as the service provider’s BGP ASN will advertise our IP network block. Under multiple carrier situations, BGP4 is required. ICANN will supply it’s own ASN and IP address space. It is expected that Internet services carriers have no packet filtering in place.
3. NO FILTERING or TRAFFIC CAPTURE: Any Internet access service including any intermediary network connections must NOT include any form of traffic filtering or traffic capture. This would include but is not limited to the following:
4. SERVICE LEVEL: Access to high-level support by the transit provider must be available 24
hours a day for the duration of the conference by the local host support staff. Troubleshooting transit and
bandwidth issues often takes place at odd times so as not to impact the conference. Direct contact information
to English-speaking support staff must be provided to the ICANN Technical Staff.
Required Network SLA:
5. INFRASTRUCTURE: The venue must have proper infrastructure installed in all spaces used by ICANN. All meeting rooms and public spaces must have at least one functional RJ-45 jack. All jacks must be wired to central wiring locations with CAT5e or better cabling. CAT5e, CAT6, or fiber optic cabling must properly interconnect wiring locations. All cabling must be tested and functional.
6. DIAGRAM: The venue must provide a diagram (DWG, JPG or PDF) to the ICANN technical staff detailing the local network infrastructure for the meeting. This would include any relevant network cross connect locations and local loop service provider(s) Minimum Point of Entry (MPOE). This should include a best effort description of available local loop service provider copper or fiber optic cables are available for new service.
7. POWER: The venue must provide adequate reliable power for all network systems. All core infrastructure devices must have UPS and generator backup power supplied to cover potential power outages. Power must be provided by dedicated circuits that are only used for infrastructure purposes and the load properly distributed. Two separate (redundant) circuits of at least 20A must be available in the MDF and one circuit of at least 15A in each IDF location. The host or venue must also provide 1KVA+ UPS units for use in the meeting rooms, IDF and MDF locations where ICANN determines they are needed.
The ICANN Meeting Technical Services staff are those people consisting of ICANN staff and their contractors assigned to manage, design and deploy technical services at the ICANN meetings. ICANN Technical staff does not include local hosts, service providers or those entities contracted by ICANN for a single meeting.
ICANN employs staff and contractors that are responsible for deployment, operation of the meeting network, telephony and audio/video broadcast services at the meeting. Services provided by ICANN contractors are not to be supplied by the host and are listed here as a notice of the potential support needs that the host will be called upon for. The expectation is that the host will provide assistance to ICANN Technical Staff to facilitate the delivery of these services.